This linear scale is based on electro magnetic induction principle thus offering you high enviroment protection IP level , in the mean time reference point is not necessary after each power on.
|
Cable length:
|
7 m
|
|
Effective range:
|
3000 mm
|
|
Delivered:
|
Mounting set
|
|
Accuracy:
|
100 to 500 mm ±5 µm
600 to 1800 mm ±7 µm 2000 to 3000 mm ±10 µm |
|
Operation temperature:
|
0°C to 45°C
|
|
Power
supply: |
5V DC ± 10%
|
|
Max. drive speed:
|
50 m/min
|
|
Signal period:
|
20 µm
|
|
Measuring method:
|
Electromagnetic induction system
|
|
Resolution:
|
0,001 / 0,005 (switchable via Counter)
|
|
L1:
|
3040 mm
|
|
L2:
|
3178 mm
|
|
L3:
|
3162 mm
|
|
L4:
|
3198 mm
|
|
L5:
|
529 mm
|
|
L6:
|
521 mm
|
|
L7:
|
530 mm
|